Stand Alone / Battery Operated Detectors

  • Product
  • Specifications

  • smoke
  • SS 168
  • 3V DC Stand-alone Smoke Alarm
  • Operating voltage: 2*1.5V AA batteries
  • Alarm current: ≤35mA
  • Audio alarm: 85Db at 3 meter
  • Temp range: -10℃ to 50℃
  • Humidity range: ≤95%RH
  • Detecting area: 80m2 at 6-12m
  • Plastic housing


  • heat
  • HD 505 / PW-560H
  • 9V DC Stand-alone Heat Alarm
  • Operating voltage: DC 9V battery
  • Alarm current: ≤30mA
  • SPL: ≥85dB/m
  • Temp. trip point: 57 Celsius
  • Operating temperature: -10~+50 Celsius
  • Working humidity: ≤95% RH
  • Detecting area: 50m2 at 6-12m

  • Product
  • Specifications

  • smoke
  • DG-822
  • 9V DC Stand-alone Smoke Alarm
  • Operating voltage: DC 9V battery
  • Alarm current: ≤35mA
  • Audio alarm: 85Db at 3 meter
  • Temp range: -10℃ to 50℃
  • Humidity range: ≤95%RH
  • Detecting area: 80m2 at 6-12m
  • Plastic housing

Conventional Fire Alarm System

  • Product
  • Specifications

    • CK 1002
    • 2 Zone Conventional Fire Alarm Panel
    • Max. 30 Devices per zone
    • 2 Sounder Zones (27V output)
    • 2 Wire or 4 Wire Sensors compatible
    • Built-in 2pcs 4.5AH battery
    • Input: AC 220V
    • Metal Housing
    • ETL listed
    • EN54 standard compliant
    • CE approved


    • CK 1008
    • 8 Zone Conventional Fire Alarm Panel
    • Max. 30 Devices per zone
    • 2 Sounder Zones (27V output)
    • 2 Wire or 4 Wire Sensors compatible
    • Built-in 2pcs 7AH battery
    • Input: AC 220V
    • Metal Housing
    • ETL listed
    • EN54 standard compliant
    • CE approved


    • CP101 08
    • 8 Zone Conventional Fire Alarm Panel
    • Max. 30 Devices per zone
    • 2 Sounder Zones (27V output)
    • 2 Wire or 4 Wire Sensors compatible
    • Built-in 2pcs 7AH battery
    • Input: AC 220V
    • Plastic Housing
    • ETL listed
    • EN54 standard compliant
    • CE compliant


    • WT-105
    • 2-Wire Conventional Heat Detector
    • w/ LED status indicator
    • Input: DC 24V
    • Detection Temp: 57C
    • EN54-7 Standard and CE Compliant
    • Plastic housing


    • YT-102
    • 2-Wire Conventional Smoke Detector
    • w/ LED status indicator
    • Input: DC 24V
    • Operating Temp: -10C to 50C
    • Sensitivity: 0.15-0.3dB/m
    • EN54-7 Standard and CE Compliant
    • Plastic housing


    • SB 116
    • Manual Call point w/ reset (Conventional)
    • Push In / Pull down
    • Plastic housing


    • MD 111
    • Remote LED status indicator
    • Input: DC 3V
    • Plastic housing

  • Product
  • Specifications

    • CK 1004
    • 4 Zone Conventional Fire Alarm Panel
    • Max. 30 Devices per zone
    • 2 Sounder Zones (27V output)
    • 2 Wire or 4 Wire Sensors compatible
    • Built-in 2pcs 7AH battery
    • Input: AC 220V
    • Metal Housing
    • ETL listed
    • EN54 standard compliant
    • CE approved


    • CP101 04
    • 4 Zone Conventional Fire Alarm Panel
    • Max. 30 Devices per zone
    • 2 Sounder Zones (27V output)
    • 2 Wire or 4 Wire Sensors compatible
    • Built-in 2pcs 7AH battery
    • Input: AC 220V
    • Plastic Housing
    • ETL listed
    • EN54 standard compliant
    • CE compliant


    • WT-105-C
    • 2-Wire Conventional Heat Detector
    • w/ LED status indicator
    • Input: DC 24V
    • Detection Temp: 57C
    • CE Complaint
    • Plastic housing


    • YT-102-C
    • 2-Wire Conventional Smoke Detector
    • w/ LED status indicator
    • Input: DC 24V
    • Operating Temp: -10C to 50C
    • Sensitivity: 0.15-0.3dB/m
    • CE Complaint
    • Plastic housing


    • SB 106
    • Manual Call point (Conventional)
    • Non-resettable
    • Plastic housing


    • JL188 6
    • 6 Mechanical Bell DC24V
    • 85dB Sound Intensity
    • EN54-3 Standard Compliant
    • Metal housing


    • SG 109
    • Sounder with LED Strobe Light
    • 90dB Sound Intensity
    • Input: DC 24V
    • Plastic housing

Addressable Fire Alarm System

  • Product
  • Specifications

    • FACP 6000 / 128
    • 1 Loop Addressable Fire Alarm Panel
    • 128 Devices per loop
    • 2 Sounder Zones (27V output)
    • 2 Wire or 4 Wire Sensors compatible
    • Built-in 2pcs battery
    • Input: AC 220V
    • Metal Housing
    • ETL listed
    • EN54 standard compliant
    • CE compliant

    • S 6001
    • 2-Wire Addressable Smoke Detector
    • w/ LED status indicator
    • Input: DC 24V
    • Operating Temp: -10C to 50C
    • Sensitivity: 0.15-0.3dB/m
    • EN54 7 Standard and CE Complaint
    • Plastic housing


    • C 6004
    • Addressable Manual Call point w/ reset
    • Push In / Pull down
    • CE Complaint
    • Plastic housing


    • Model: BL 6
    • Addressable Mechanical Bell
    • Input: DC 24V
    • 85dB Sound Intensity
    • Metal housing


    • S 201
    • Addressable Sounder w/ LED Indicator
    • Input: DC 24V
    • 90dB Sound Intensity
    • EN54 3 Standard Compliant
    • Plastic housing

  • Product
  • Specifications

    • H 6002
    • 2-Wire Addressable Heat Detector
    • w/ LED status indicator
    • Input: DC 24V
    • Detection Temp: 57C
    • EN54 7 Standard and CE Complaint
    • Plastic Housing

    • P 6010
    • Address Programmer
    • Compatible for detectors, modules, sounder, etc
    • Input: 2pcs AAA batteries

    • M 6007 I
    • Addressable Input Module
    • w/ LED status indicator
    • Input: DC 24V
    • Operating Temp: -10C to 50C
    • CE Complaint
    • Plastic housing


    • M 6007 O
    • Addressable Output Module
    • w/ LED status indicator
    • Input: DC 24V
    • Operating Temp: -10C to 50C
    • CE Complaint
    • Plastic housing

    • M 6006
    • Short Isolator Module
    • Protects devices from Short circuit
    • Max: 30 devices per isolator
    • Input: DC24V